Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
1.
Artif Organs ; 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38577853

RESUMEN

PURPOSE: LVAD outflow graft stenosis continues to remain prevalent with a high complication rate. We sought to pool the existing evidence on indications, utilization patterns, and outcomes of transcatheter interventions for outflow graft stenosis in the HeartMate 3 LVAD. METHODS: An electronic search was performed to identify all studies in the English literature reporting on HeartMate 3 LVAD outflow graft stenting. Patient-level data were extracted for analysis. RESULTS: Thirteen published reports and one unpublished case comprising a total of 28 patients were included. Median patient age was 68.5 years [Interquartile range: 58, 71] and 25.9% (7/27) were female. Dyspnea [60.7% (17/28)] was the most common presenting symptom. Low flow alarms were present in 60% (15/25) of patients. Findings included external compression [35.7% (10/28)], graft twist [21.4% (6/28)], graft twist and external compression [14.3% (4.28)], intraluminal thrombus [10.7% (3/28)], graft twist and intraluminal thrombus [3.6% (1/28)], and pseudoaneurysm of outflow graft [3.6% (1/28)]. Median time from LVAD implantation to stenting was 2.1 years [1.4, 3]. Immediate flow normalization after stenting was observed in 85.7% (24/28). The 30-day mortality was 12% (3/25). Overall mortality was 12% (3/25) at a median follow-up of 3.9 months [1, 17]. CONCLUSION: Outflow graft stenting in the HeartMate 3 LVAD appears to be a reasonable treatment option for outflow graft stenosis, with low overall rates of complications and mortality. Further refinement of indications and approaches may improve outcomes.

2.
Am J Transplant ; 24(3): 380-390, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38072122

RESUMEN

Patients with severe heart disease may have coexisting liver disease from various causes. The incidence of combined heart-liver transplant (CHLT) is increasing as more patients with congenital heart disease survive to adulthood and develop advanced heart failure with associated liver disease from chronic right-sided heart or Fontan failure. However, the criteria for CHLT have not been established. To address this unmet need, a virtual consensus conference was organized on June 10, 2022, endorsed by the American Society of Transplantation. The conference represented a collaborative effort by experts in cardiothoracic and liver transplantation from across the United States to assess interdisciplinary criteria for liver transplantation in the CHLT candidate, surgical considerations of CHLT, current allocation system that generally results in the liver following the heart for CHLT, and optimal post-CHLT management. The conference served as a forum to unify criteria between the different specialties and to forge a pathway for patients who may need dual organ transplantation. Due to the continuing shortage of available donor organs, ethical issues related to multiorgan transplantation were also debated. The findings and consensus statements are presented.


Asunto(s)
Trasplante de Corazón , Hepatopatías , Trasplante de Hígado , Humanos , Corazón
4.
Clin Transplant ; 37(12): e15150, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37924498

RESUMEN

BACKGROUND: Predicted heart mass (PHM) is a commonly used tool for donor-to-recipient size matching. However, incorporating body weight as part of PHM can be considered problematic given its high variability, and low metabolic nature of fat. We sought to assess whether substituting the actual donor and recipient weight with the ideal body weight (IBW) would affect the association of donor-to-recipient PHM ratio with 1-year and overall survival after heart transplantation. METHODS: The United Network for Organ Sharing (UNOS) database was queried for adult patients who received a primary heart transplant between January 2000 and September 2021. RESULTS: Both PHM and ideal PHM (IPHM) ratios were associated with one-year (PHM: p = .003; IPHM: p = .0007) and overall (PHM: p = .02; IPHM: p = .02) survival. In the continuous analysis with restricted cubic splines, both PHM (p = .0003) and IPHM (p = .00001) were associated with relative hazards of death. CONCLUSION: IPHM is significantly associated with post-transplant survival and may be a useful compliment to PHM.


Asunto(s)
Trasplante de Corazón , Peso Corporal Ideal , Adulto , Humanos , Estudios Retrospectivos , Donantes de Tejidos , Supervivencia de Injerto
5.
Artif Organs ; 47(10): 1559-1566, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37537953

RESUMEN

BACKGROUND: Veno-arterial-venous extracorporeal membrane oxygenation (V-AV ECMO) is a less commonly used configuration of ECMO. We sought to understand the indications, utilization patterns, and outcomes of V-AV ECMO by quantitatively pooling the existing evidence from the literature. METHODS: Electronic search was performed to identify all relevant studies reporting V-AV ECMO usage. Five studies comprising 77 patients were selected and cohort-level data were extracted for further analysis. RESULTS: Mean patient age was 61 (95% CI: 55.2, 66.5) years and 30% (23/77) were female. The majority of cases [91% (70/77)] were transitioned to V-AV ECMO from another pre-existing ECMO configuration: V-A ECMO in 55% (42/77) vs. V-V ECMO in 36% (28/77), p = 0.04. Only 9% (7/77) of cases were directly placed on V-AV ECMO. The mean duration of hospital stay was 42.3 (95% CI: 10.5, 74.2) days, while ICU mortality was 46% (29, 64). Transition to durable left ventricular assist device was performed in 3% (2/64) of patients, while 3% (2/64) underwent heart transplantation. V-AV ECMO was successfully weaned to explantation in 33% (21/64) of patients. CONCLUSION: V-AV ECMO is a viable option for optimizing cardiopulmonary support in selected patients. Survival to weaning or bridging therapy appears comparable to more common ECMO configurations.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Trasplante de Corazón , Corazón Auxiliar , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
6.
Gen Thorac Cardiovasc Surg ; 71(12): 723-729, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37310563

RESUMEN

OBJECTIVE: Although an ultrasonic harmonic scalpel (HS) has been used to harvest the internal mammary artery (IMA) for coronary artery bypass grafting, the benefits and risks compared to conventional electrocautery (EC) are not clear. We aimed to compare the outcomes of HS versus EC for IMA harvesting. METHODS: An electronic search was performed to identify all relevant studies. Baseline characteristics, perioperative variables, and clinical outcomes were extracted and pooled for meta-analysis. RESULTS: This meta-analysis included 12 studies. Pooled analyses demonstrated that both groups had comparable preoperative baseline characteristics including age, gender, and left ventricular ejection fraction. HS included more diabetic patients [33% (95% CI 30, 35) vs. 27% (23, 31), p = 0.01]. Harvest time for unilateral IMA was significantly longer with HS than EC [39 (31, 47) minutes vs. 25 (17, 33) minutes, p < 0.01]. However, the rate of pedicled unilateral IMA was significantly higher for EC compared with HS [20% (17, 24) vs. 8% (7, 9), p < 0.01]. The rate of intact endothelium was significantly higher with HS than EC [95% (88, 98) vs. 81% (68, 89), p < 0.01). There was no significant difference in postoperative outcomes including bleeding [3% (2, 4)], sternal infection [3% (2, 4)], and operative/30-day mortality [3% (2, 4)]. CONCLUSIONS: HS required longer IMA harvest times which could be partially attributed to a higher skeletonization rate in this category. HS may cause less endothelial injury than EC; however, no significant differences in postoperative outcomes were seen between the groups.


Asunto(s)
Arterias Mamarias , Ultrasonido , Humanos , Volumen Sistólico , Función Ventricular Izquierda , Electrocoagulación/efectos adversos
7.
Artículo en Inglés | MEDLINE | ID: mdl-37196673

RESUMEN

BACKGROUND: Several factors affect heart transplant (HTx) and lung transplant (LTx) program outcomes. Variabilities in institutional and community characteristics have been shown to influence survival. At present, half of HTx centers in the United States do not possess a concomitant LTx program. This study sought to better understand the characteristics of HTx with and without LTx programs. METHODS: Nationwide transplant data were collected from the Scientific Registry of Transplant Recipients (SRTR) in August 2020. SRTR star rating ranges from tier 1 (lowest) to tier 5 (highest). HTx volumes and SRTR star ratings for survival were compared between the centers with heart-only (H0) programs and the centers with heart-lung (HL) programs. RESULTS: SRTR star ratings were available for 117 transplant centers with one or more HTx reported. The median number of HTx performed over 1 year was 16 (interquartile range [IQR]: 2-29). The number of HL centers (n = 67, 57.3%) were comparable to H0 centers (n = 50, 42.7%; p = 0.14). The HTx volume at the HL centers (28 [IQR: 17-41]) exceeded the HTx volume at the H0 centers (13 [IQR: 9-23]; p < 0.01), but were comparable to the LTx volume at the HL centers (31 [IQR: 16-46]; p = 0.25). The median HTx one-year survival rating was 3 (IQR: 2-4) at both the H0 and HL centers (p = 0.85). The HTx and LTx volumes were positively associated with the respective 1-year survivals (p < 0.01). CONCLUSION: While the presence of an LTx program is not directly associated with HTx survival, it has a positive association with the HTx volume. The HTx and LTx volumes are positively associated with the 1-year survival.

8.
Artículo en Inglés | MEDLINE | ID: mdl-36652964

RESUMEN

BACKGROUND: Predicted cardiac mass (PCM) has been well validated for size matching donor hearts to heart transplantation recipients. We hypothesized that cardiothoracic ratio (CTR) could be reflective of recipient-specific limits of oversizing, and sought to determine the utility of donor to recipient PCM ratio (PCMR) and CTR in predicting delayed chest closure after heart transplantation. METHODS: A retrospective review of prospectively collected data on 38 consecutive heart transplantations performed at our institution from 2017 to 2020 was performed. Donor and recipient PCM were estimated using Multi-Ethnic Study of Atherosclerosis predictive models. Receiver operating characteristic analysis was performed to determine the discriminatory power of the ratio of PCMR to CTR in predicting delayed sternal closure. RESULTS: Of the 38 patients, 71.1% (27/38) were male and the median age at transplantation was 58 (interquartile range [IQR]: 47-62) years. Ischemic cardiomyopathy was present in 31.6% of recipients (12/38). Median recipient CTR was 0.63 [IQR: 0.59-0.66]. Median donor to recipient PCMR was 1.07 [IQR: 0.96-1.19], which indicated 7% oversizing. Thirteen out of 38 (34.2%) underwent delayed sternal closure. Primary graft dysfunction occurred in 15.8% (6/38). PCMR/CTR showed good discriminatory power in predicting delayed sternal closure [area under the curve: 80.4% (65.3-95.6%)]. PCMR/CTR cut-off of 1.7 offered the best trade-off between the sensitivity (69.6%) and specificity (91.7%). CONCLUSION: CTR could be helpful in guiding the recipient-specific extent of oversizing donor hearts. Maintaining the ratio of PCMR to CTR below 1.7 could avoid excessive oversizing of the donor heart.

9.
Artif Organs ; 47(6): 934-942, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36691820

RESUMEN

BACKGROUND: Microaxial circulatory support devices have been used to support patients treated with percutaneous coronary intervention (PCI) for acute myocardial infarction complicated by cardiogenic shock (AMICS). The purpose of this systematic review and meta-analysis was to pool and analyze the existing evidence on the baseline characteristics, periprocedural data, and outcomes of microaxial support before and after PCI in AMICS. METHODS: An electronic database search was performed to identify all cohort studies on Impella and PCI for cardiogenic shock in the English language. A total of five articles comprising 543 patients were included. These patients received microaxial support either before (pre-PCI) or after (post-PCI) undergoing PCI. Comparative analyses were done between both groups. RESULTS: The mean patient age was 66 years [95% Confidence Interval (58-74)], and 22% (89/396) of patients were female. ST-elevation myocardial infarctions (MI) comprised 64% (44-80) of MIs and 50% (44-56) of MIs involved the left anterior descending artery. The mean number of diseased vessels was 2.21 (1.62-2.80). The mean left ventricular ejection fraction was 31% (23.4-38.6). The mean arterial pressure was 66.3 mm Hg (54.1-78.5). Mean serum lactate [6.1 mmol/L (3.3-8.9)] and serum creatinine [1.4 mg/dl (1.0-1.7)] were similar between groups. 30-day mortality was lower in the pre-PCI group [41% (34%-49%)] compared to the post-PCI group [61% (42%-77%), p < 0.01]. Pooled Kaplan-Meier analysis showed better early survival in the pre-PCI group (p < 0.001). CONCLUSION: Patients presenting with AMICS were similar at baseline in both pre-PCI and post-PCI groups. Nevertheless, pre-PCI group showed better early survival compared to post-PCI group.


Asunto(s)
Corazón Auxiliar , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Femenino , Anciano , Masculino , Choque Cardiogénico/terapia , Intervención Coronaria Percutánea/efectos adversos , Volumen Sistólico , Corazón Auxiliar/efectos adversos , Función Ventricular Izquierda , Infarto del Miocardio/complicaciones , Resultado del Tratamiento
10.
Artif Organs ; 47(2): 246-247, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36576449
15.
Artif Organs ; 46(6): 987-994, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35451522

RESUMEN

Scientific barriers that have prevented successful xenotransplantation are being breached, yet many ethical issues remain. Some are broad issues that accompany the adoption of novel and expensive technologies, and some are unique to xenotransplantation. Major ethical questions include areas such as: viral transmission; zoonoses and lifetime surveillance; interfering with nature; efficacy, access, and expense; treatment of animals; regulation and oversight.


Asunto(s)
Zoonosis , Animales , Trasplante Heterólogo , Zoonosis/prevención & control
17.
Clin Transplant ; 36(5): e14598, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35048435

RESUMEN

STUDY: There is no widely accepted donor to recipient size-match metric to predict outcomes in cardiac transplant. The predictive ability of size-match metrics has not been studied when recipients are stratified by heart failure etiology. We sought to assess the performance of commonly used size metrics to predict survival after heart transplant, accounting for restrictive versus non-restrictive pathology. METHODS: The UNOS registry was queried from 2000 to 2017 for all primary isolated heart transplants. Donor-recipient ratios were calculated for commonly used size metrics and their association with survival was assessed using continuous, nonlinear analysis. RESULTS: 29 817 patients were identified. Height (P < .001), predicted heart mass (PHM) (P = .003), ideal body weight (IBW) (P < .001) and body mass index (BMI) (P = .003) ratios were significantly associated with survival, while weight and body surface area (BSA) ratios were not. When stratified, only BMI ratio retained significance for both restrictive (P = .051) and non-restrictive (P = .003) subsets. Recipients with restrictive etiology had increased risk of mortality with both a lower and higher BMI ratio. CONCLUSIONS: While many metrics show association with survival in the non-restrictive subset, BMI is the only metric that retains significance in the restrictive subset. Recipients with restrictive and non-restrictive etiologies of heart failure tolerate size mismatch differently.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Obtención de Tejidos y Órganos , Benchmarking , Supervivencia de Injerto , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón/efectos adversos , Humanos , Tamaño de los Órganos , Estudios Retrospectivos , Donantes de Tejidos
18.
Clin Transplant ; 36(2): e14567, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34927287

RESUMEN

PURPOSE: Heparin-induced thrombocytopenia (HIT) presents a unique challenge in patients requiring orthotopic heart transplantation (OHT). We sought to pool the existing evidence in a systematic review. METHODS: Electronic search was performed to identify all relevant studies on OHT in patients with HIT. Patient-level data for 33 patients from 21 studies were extracted for statistical analysis. RESULTS: Median patient age was 51 [IQR 41, 55] years, with 75.8% (25/33) males. All patients had a clinical diagnosis of HIT, and anti-PF4/Heparin antibodies were positive in 87.9% (29/33). Median lowest reported platelet count was 46 × 109 /L [27.2, 73.5]. Intraoperatively, 61% (20/33) of patients were given unfractionated heparin (UFH), while 39% (13/33) were given alternative anticoagulants. The alternative agent subgroup required more antifibrinolytics [54% (7/13) vs 10% (2/20), P = .02] and clotting factors [69.2% (9/13) vs 15.0% (3/20), P < .01]. Perioperative thrombosis occurred more [53.8% (7/13) vs 0% (0/20, P < .01) in alternate agent subgroup. More patients in the alternate agent subgroup required post-operative transfusions [54% (7/13) vs 0% (0/20), P < .01]. Thirty-day mortality of 15.2% (5/33) was comparable between the subgroups. CONCLUSION: Heparin use during OHT may be associated with less adverse effects compared to use of other anticoagulants with no difference in 30-day mortality.


Asunto(s)
Trasplante de Corazón , Trombocitopenia , Trombosis , Anticoagulantes/efectos adversos , Heparina/efectos adversos , Humanos , Masculino , Trombocitopenia/inducido químicamente
19.
J Am Soc Echocardiogr ; 35(5): 460-468, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34954049

RESUMEN

BACKGROUND: Accurate expected effective orifice area (EOA) values for balloon-expandable (BE) transcatheter heart valves (THV) are crucial for preventing patient-prosthesis mismatch (PPM) and assessment of THV function. Currently published reference EOAs, however, are based on transthoracic echocardiography (TTE), which may be subject to left ventricular outflow tract diameter underestimation and/or suboptimal THV Doppler interrogation. The objective of this study was to establish reference EOA values for BE THVs on the basis of Doppler and three-dimensional (3D) transesophageal echocardiography (TEE). METHODS: Two hundred twelve intraprocedural transesophageal echocardiographic examinations performed during BE THV implantation with optimal postimplantation Doppler and 3D imaging were retrospectively reviewed. Continuity equation-derived EOAs were compared with geometric orifice areas by 3D planimetry (GOA3D). Performance indices (i.e., EOA normalized to valve size) and PPM rates were determined. TTE-based EOAs obtained within 30 days were also calculated in a subset of 170 patients. RESULTS: The average EOA for all BE THV valves (77% SAPIEN 3) was 2.3 ± 0.5 cm2, while the average EOA was 1.6 ± 0.2 cm2 for 20-mm, 2.0 ± 0.2 cm2, for 23-mm, 2.5 ± 0.3 cm2 for 26-mm, and 3.0 ± 0.3 cm2 for 29-mm THV size (P < .001). Bland-Altman analysis demonstrated very good agreement between EOA and GOA3D (bias -0.04 ± 0.15 cm2). There were strong correlations between annular area and TEE-based EOA (R = 0.84) and GOA3D (R = 0.87). The mean performance index was 47 ± 5% and was similar for all THV sizes (P = .21). EOAs based on TTE were smaller compared with those based on TEE, while the correlation with annular area (R = 0.67) and agreement with GOA3D (bias -0.26 ± 0.43 cm2) was not as strong. The overall PPM rate was 2% in the TEE cohort and 12% in the TTE cohort. CONCLUSIONS: EOAs for BE THVs based on intraprocedural Doppler and 3D TEE suggest that previously published TTE-based reference values for EOA are underestimated, while PPM rates may be overestimated. Our findings have important clinical implications for preimplantation decision-making and for the evaluation of THV hemodynamics and function during follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Ecocardiografía , Ecocardiografía Transesofágica , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...